EN
High Pressure (0-4MPa) Water Electrolysis Hydrogen Production Test Bench
Equipment Description:

High Pressure Water Electrolysis Hydrogen Production Test Bench is a special equipment for R&D, performance evaluation and quality inspection of electrolyzers (or electrolyzer stacks) under high-pressure conditions.It can accurately simulate and control the operation of electrolyzers under high pressure in a laboratory environment, and comprehensively evaluate performance, efficiency, durability and safety.Types include:PEM, Alkaline and Seawater Water Electrolysis Hydrogen Production Test Benches.


Equipment Advantages:

1. It can directly produce medium and high-pressure hydrogen, greatly reducing or eliminating the need for rear-end hydrogen compressors and their high power consumption, significantly lowering overall system operation cost and equipment complexity.

2. It can test the sealing performance, hydrogen embrittlement resistance, structural strength and long-term stability of electrolyzers in a real high-pressure environment, which is an irreplaceable core step compared with low-pressure testing and directly related to product safety and service life.

3. It can study the influence of pressure on key electrochemical performance such as reaction kinetics, ohmic resistance and gas crossover of electrolyzers, providing accurate data for the optimal design of high-pressure electrolyzers.

4. High-pressure environment puts forward higher requirements for gas purity management and safety monitoring. The test bench can verify the performance of high-pressure gas-liquid separation and purification modules, and is integrated with high-level safety interlocks such as overpressure relief to ensure system safety.
Specifications
Key Parameters Parameter Values
Power Module Power 1-5KW
Power Module Voltage Range 0~15V, accuracy ≤±0.05% F.S.
Power Module Current 0~350A, accuracy ≤±0.5% F.S.
Hydrogen & Oxygen Backpressure Range Normal pressure - 40bar, accuracy ≤±0.5% F.S.
Water Flow Range Max flow rate 800 ml/min, accuracy ≤±1% F.S.
Temperature Control Range RT-95℃, control accuracy ≤±0.5℃
Temperature Rise Rate ≤5°C/min
CVM Patrol Inspection Max 1024 channels, range: -5~+5V, accuracy ±1mV
Hydrogen-in-Air Sensor Range: 0~2%, accuracy: ≤±2% F.S., can calibrate to smaller measurement range
Oxygen-in-Hydrogen Sensor Range: 0~2%, accuracy: ≤±2% F.S., can calibrate to smaller measurement range
Case Study
Business Inquiry
If you need to know more details, you can leave a message for consultation, and our consultants will provide you with more information and materials